Wednesday, June 5, 2019

Medical Treatment Using Computed Tomography (CT)

Medical Treatment Using Computed Tomography (CT)Breast PlanPart OneTreatment Site / diagnosis Left BreastTreatment Modality 2 Dimensional tangentialType of Patient Data Computed tomography and virtual showTechnique Isocentricprescription drug Iso pane 40GY in 15Part TwoComputed tomography (CT) was employed as an imaging modality for this finenessment. In general, CT is the standard imaging modality employed. This is ascribable to the ability of CT to provide a 3 Dimensional image of the tumour and the ordinary anatomy in that area, CT is particularly effective in visualising bony anatomy. It also provides the electron density data essential to enable accurate dose calculation and visualizening. Although CT scanning is the standard for treatment localisation, charismatic resonance imagining (MRI) are superior in defining soft tissue and tumour metastasis and so it is now advisable to employ CT-MRI fusion imaging in localize to improve the accuracy of tumour localisation for tr eatment (Bhide and Nutting 2010).Tangential fields are normally used in the treatment of tumours of the rapper. Virtual simulation (v-sim) is employed in order to generate lateral and medial tangential fields. V-sim ensures accurate field matching and acceptable reportage of the pap tissue, the chest environ and the surgical or mastectomy scar (Barrett and Dobbs et al. 2009 and Moran and Haffty 2009).Part ThreeThe choice of tool energy is heavily dependent on patient size and separation in general the chosen beam energy is 6 Megavoltage. For patients with a separation greater than 22cm, higher energy beams are usually used in order to improve dose homogeneity. Higher energy beams reduce the skin sparing effect of a lower energy therefore wield should be interpreted to ensure there is sufficient coverage of the superficial breast, mastectomy scar and clinical boarders (Barrett, Dobbs et al. 2009).The breast is traditionally treated by means of two dimensional conformal tangentia l beams. The beam arrangement is a lateral and medial beam. The field boarders are marked up clinically, usually by a specialist radiographer. The lateral beam is usually at mid axilla and the medial beam at sternal level. The beams are at tangents to each other avoid irradiation of the tit, lung, dose uniformity and no dose overlap to the contralateral breast (Lee and Harris 2009).Segmented beams were also selected in order to improve Planning Target Volume (PTV) coverage and allow for Multi Leaf Collimator (MLC) shielding without compromising coverage of the PTV whilst shielding out undesired hot spots that naturally happen in the inframammary fold of the breast tissue (Nakamura, Hatanaka et al. 2011).According to a study by Purdy 2004 ICRU 50 guidelines states that the isodose diffusion within the PTV must be amidst 95% 107% .In order to achieve best dose distribution wedged beams are employed, wedges are tissue compensators that account for missing tissue in order to impro ve the homogeneity of the dose distribution (Barrett, Dobbs et al. 2009). This is particularly important in breast treatments due to the contour of the breast. The anterior surface of the breast is less dense than the tissue toward the chest bulwark, hotspots tend to occur around the areola for this reason wedges in this plan are 60 and orientated with the thick end anterior in order to distribute the dose away from the nipple and conform more homogenously to the chest wall. There are also wedges on the segments in order to improve dose homogeneity in the superior/ inferior direction and to ensure acceptable PTV coverage (Haffty, Buchholz et al. 2008).Part 4There is acceptable coverage of the CTV, in breast treatment, the aim is to treat all the breast tissue to the deep fascia the 95% isodose should conform to the chest wall but not include the pectoralis major (Barrett, Dobbs et al. 2009). The breast tissue is covered by the 95% isodose line and it adheres well to the muscles of the chest wall. There are no hot spots present within the plan due to the optimal use of tissue compensators as mentioned above. According to a study by Purdy in 2004, ICRU guidelines isodse distribution must be kept between 95% 107%, MLC shielding on the segments were employed in order to shield any hotspots present within the CTV without compromising target coverage or causing the plan to become too cold.Part 5The critical organs that were contoured were the left lung. Although there is no dose volume histogram associated with breast treatments, there should be no more than 2cm of lung volume included in the treatment field in order to prevent late toxicities such as lung fibrosis and pneumonitis. It is also advisable to contour the heart on left sided breast treatments.Part 6This plan is clinically acceptable, however as the treatment is being delivered to the left side, the heart should be taken into consideration. Deep inspiration snorkel hold (DIBH) is becoming more common for left sided breast treatments. DIBH involves treating the patient on inspiration and breath hold through coaching either auditory or visually or both. During inspiration the breast tissue is lifted off the chest wall and thus results in less cardiac tissue and lung being irradiated (Vikstrm, Hjelstuen et al. 2011).Not all patients are suitable for DIBH if they cannot remain in breath hold for the continuance of time it takes to deliver the beam. However it is still important to remove the heart from the high dose area, this is achievable by the use of cardiac shielding created by MLCS. Although this has shown a reduction in the dose received by the heart, it also risks underdoing of the target (Bartlett, Yarnold et al. 2013).ReferencesBarrett, A., J. Dobbs, et al. (2009). Practical Radiotherapy Planning Fourth Edition, CRC Press.Bartlett, F. R., J. R. Yarnold, et al. (2013). Multileaf Collimation Cardiac Shielding in Breast Radiotherapy Cardiac Doses are Reduced, But at What Cos t? Clinical Oncology 25(12) 690-696.Bhide, S. and C. Nutting (2010). Recent advances in radiotherapy. BMC medicine 8(1) 25.Haffty, B. G., T. A. Buchholz, et al. (2008). Should intensity-modulated radiation therapy be the standard of care in the conservatively managed breast cancer patient? Journal of Clinical Oncology 26(13) 2072-2074.Lee, L. J. and J. R. Harris (2009). Innovations in radiation therapy (RT) for breast cancer. The Breast 18 S103-S111.Moran, M. S. and B. G. Haffty (2009). Radiation Techniques and Toxicities for Locally innovational Breast Cancer. Seminars in Radiation Oncology 19(4) 244-255.Nakamura, N., S. Hatanaka, et al. (2011). Quantification of cold spots caused by geometrical uncertainty in field-in-field techniques for whole breast radiotherapy. Japanese journal of clinical oncology 41(9) 1127-1131.Purdy, J. A. (2004). trustworthy ICRU definitions of volumes limitations and future directions. Seminars in Radiation Oncology, Elsevier.Vikstrm, J., M. H. Hjelstu en, et al. (2011). Cardiac and pulmonary dose reduction for tangentially irradiated breast cancer, utilizing deep inspiration breath-hold with audio-visual guidance, without compromising target coverage. Acta Oncologica 50(1) 42-50.

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.